Milesight UC512 LoRaWan IoT Controller with Latching Solenoids and Pulse Meter support Store Link Supported Commands (12) Name Description Version Requirements Update Valve Status - Pulse Limit Open or close a device valve until a specified number of pulses have gone through. Toggle Data Retransmission Enable/Disable data retransmission on network outtage Update Valve Status Immediatly open or close a device valve Set Counter Initial Value Set pulse counter initial value Reboot Reboot the device Set Reporting Interval Change the rate at which the device uplinks data Update Valve Status - Time Period Open or close a device valve for a specific amount of time Reset GPIO Counter Reset the counter for a GPIO pin Set Pulse Filter Filter the pulse counting values below this rate. This only works when the GPIO working mode is 'Water Volume Counter'. Applies to both
GPIO interfaces. Set Command Response Time Set the interval at which the device will check for commands — a lower interval results in lower command execution latency, at the cost of higher battery consumption. Set Data Retransmission Delay Set the delay after a network reconnect to resend data. For this setting to take effect, both data storage and data retransmission must be enabled. Set Collection Interval The interval for collecting data when there is an alarm command. This interval must not be more than the reporting interval.